"Linear" wall-mount adapters
"Linear" desk-top adapters
Switching wall-mount & desk-top
Small power transformers
Coils, filters, inductors, and converters

Download ENG catalogs (pdfs) Text based site navigation map
 

Request-for-Quote form "Help"

 

Mounting Type:
Please check the mounting option you need: Printed Circuit Board Vertical, Printed Circuit Board Horiztonal, or Chassis Mount. Should you require special mounting dimensions, please put them in the "notes" section at the bottom.

Input Type:
You may choose either a "single" input or a "dual" input. Then select the input voltage /frequency needed in the drop-down box.

Output Ratings:
Enter the output "voltage" and "load current" in milliAmps (mA) needed for the output. If two outputs are required, then enter the 2nd set of values in "Output #2" fields.

Terminations:
We offer many different output terminations. Printed Circuit pins (put any foot-print spacing requirements in "notes"), Lead Wires (add the color and length requirements to "notes"), Quick-Connect Terminals (note the male/female, insulated/uninsulated, and size options), Solder Lugs, and "Other" for any additional termination requirements that may be needed.

Ambient Temperature:
Please enter the ambient temperature where the transformer will be used. Definition = The still-air temperature of the environment in which the adapter/transformer is operating. e.g., "room temperature."

Maximum Temperature Rise:
Maximum measure of heat a unit may generate above a given ambient temperature (see above).

Transformer Size:
Enter any height, width, and length requirements you may have.

Hi-Pot (dielectric):
Enter needed dielectric strength required. Definition = Used to confirm if the break-down voltage of a unit's internal insulation exceeds the minimum requirement.  Testing is done by applying high voltage between two isolated points such as primary to secondary, primary to ground, or secondary to ground for a very brief period.

Safety Agency Approvals:
Please select the required UL safety approval standard number. Should you require a safety standard not listed, please add it to the "additional notes" section.

Additional Notes:
Any additional parameters not met by the above standard options can be entered in this multi-line area.

Quote Quantities and FOB Point:
- On catalog units we can quote as low as 1k pieces (however design parameters and such may make this go higher).
- The FOB Point is the location from which the customer takes possession of the goods and from which point they cover all freight, duty, and other charges. For instance an FOB Point of Chicago, IL would mean that ENG would have taken care of all freight and duty charges getting the parts to this point. The customer would only have to "truck" the parts from Chicago to their location. Even in this case, ENG will advise the trucker to pick up and deliver the parts to your location on your account.

Contact Information:
Please fill out this section and advise how we should provide you with our quote on the RFQ (request-for-quote) form. Thank you.

 

info@engelectric.com